粒体水分量の高周波特性に及ぼす影響(第三報) ―測定用コイルのQの変化について―

http://hdl.handle.net/10105/4821
http://hdl.handle.net/10105/4821
02d9e939-77d3-4c0c-9186-a118c63f1760
名前 / ファイル ライセンス アクション
NUE9_2_57-65.pdf NUE9_2_57-65.pdf (410.7 kB)
アイテムタイプ 紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-12-20
タイトル
タイトル 粒体水分量の高周波特性に及ぼす影響(第三報) ―測定用コイルのQの変化について―
言語
言語 jpn
資源タイプ
資源タイプ departmental bulletin paper
著者 服部, 耐吉

× 服部, 耐吉

服部, 耐吉

Search repository
著者(ヨミ)
姓名 ハットリ, タイキチ
著者別名
姓名 HATTORI, Taikichi
抄録
内容記述タイプ Abstract
内容記述 In the case of measuring 'Q' of the coil in which the hydrous granular medium is inserted, the water content in it correlates with the value of 'Q'. The condition that the value of 'Q' changes at the constant water content, is decided by reactance and diameter of the measuring coil. So experiments are performed under the condition of applying the frequency ranging from 500 KC to 5.0 MC, by using the measuring coils of different inductance which have the same diameter. Two equivalent circuits represent the measuring coil in which the hydrous medium is loaded : the inductive phenomenon is mainly considered for one equivalent circuit when the medium contains more water , and the dielectric phenomenon chiefly for the other in the case of less water content. Thus, results of experiments are as follows : (1) The coil of small inductance has higher value of ⊿Q than that of large inductance at the constant frequency. (2) In the case of the same coil, the higher frequency is, the more ⊿Q grows. On the other hand, the value of measurement fluctuates at the high frequency. It is accordingly important for the improvement of measurement that the suitable frequency to the measuring coil is selected. (3) When W indicates water content, at the water content ranging from 5% to 25%, d(⊿Q)/dW is almost constant and though ⊿Q-W curve has the same direction of inclination as Rx-W curve informed on the report (I), the former is sharper than the latter; i.e., we expect better results by this experiment than by experiment informed on the report (I). Being independent of the granule-diameter and inductance of coil, 'Q' holds the minimum value at 29% or 30% in water content, and the results of measurement have a tendency to fluctuate in the vicinity of this value, because resonance becomes dull in this range. (4) The ⊿Q-W curve made a reseach for the granular medium of the large diameter is sharper than that of small diameter at the water content ranging from 25% to 10%, on the contrary, below 105& in water content d(⊿Q)/dW decreases as compared with that of smaller diameter. And the finer the granule is, the smaller the fluctuation of measurement becomes.
書誌情報 奈良学芸大学紀要

巻 9, 号 2, p. 57-65, 発行日 1960-02-15
ISSN
収録物識別子タイプ ISSN
収録物識別子 0369321X
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00180996
著者版フラグ
出版タイプ VoR
その他のタイトル
その他のタイトル Effect of Granule containing Water on High Frequency Characteristics (III) ―On Changes of Q in the Coil for Measurement―
出版者
出版者 奈良学芸大学
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 11:16:51.964187
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3